MULTICAL® 803
Kamstrup A/S · Technical description · 5512-2360_A1_GB_02.2019
6.4.2 Setup parameters
The table below shows the parameters that can be changed via the SETUP loop. Below the table, a detailed
explanation of the individual parameters is found.
SETUP loop
Index number
in display
1
Customer number (N
o
1)
3-001
2
Customer number (N
o
2)
3-002
3
Date
3-003
4
Time
1
3-004
5
Yearly target date 1 (MM.DD)
3-005
6
Monthly target date 1 (DD)
3-006
7
Flow sensor position: Inlet or outlet flow (A code)
3-007
8
Energy unit (B code)
(Can be set to kWh, MWh, GJ and Gcal)
3-008
9
Primary address of module slot 1 (N
o
34)
3-009
10
Primary address of module slot 2 (N
o
34)
3-010
11
Primary address of module slot 3 (N
o
34)
3-011
12
Primary address of module slot 4 (N
o
34)
3-012
13
Averaging period of min./max P and Q
3-013
14
Heat/cooling shift (θ
hc
)
2
(Only active on meter type 6)
3-014
15
Temperature sensor offset (t
r0
)
3
3-015
16
Radio on/off
3-016
17
Input A1 (preset register)
3-017
18
Input B1 (preset register)
3-018
19
Meter number of Input A1
3-019
20
Meter number of Input B1
3-020
21
TL2
3-021
22
TL3
3-022
23
TL4
3-023
24
Preset t5
3-024
25
EndSetup
3-025
1
In addition to adjusting the clock via the SETUP loop, the clock and the date can also be changed via METERTOOL
HCW and the modules.
2
θ
hc
can only be changed in meters configured as meter type 6. On this meter type, the user can both change
θ
hc and
disable the function. If users attempt to access this menu in calculators configured as other meter types, the message
“OFF” is displayed.
3
This function can have been disabled via the selected country code.