A-2 SCAN EXAM
A. Technical Speci cations
A.2 Imaging Plates and hygiene bags
IMAGING PLATES (IP)
Size Size 0 Size 1 Size 2 Size 3 Size 4C
Dimensions
(mm)
22 x 31 24 x 40 31 x 41 27 x 54 48 x 54
nominal
Image size
(pixels)
734 x
1034
800 x
1334
1034 x
1368
900 x
1800
1600 x 1800
nominal
Image size (MB) 1.44 2.03 2.69 3.09 5.49
nominal
Storage
environment
Imaging plates must be stored in their protective box below
33
°C. The box must be kept closed to remain dust free.
Material Photo-stimulable phosphorous material uniformly coated on a
support plastic material. Shielded with a top coat layer on the
active surface and encapsulated with lacquer around edges.
Imaging plates do not include phosphor.
Use The typical service life for an imaging plate is several hundreds
of cycles provided that the imaging plate is handled with care
and according to the supplied instructions.
The use of genuine hygiene accessories (protective covers and
hygiene bags) will extend the service life of the imaging plates.
Disposal Imaging plates are industrial waste and must be disposed of in
accordance with local and national regulations concerning the
disposal of such material.
Never use damaged imaging plates.
HYGIENE BAGS
Material Food-grade polyethylene - Latex free
Packaging Supplied in boxes
Use For the best performance it is recommended that the hygiene
bags are used within two years from the date of manufacture.
The date of manufacture is printed on the bottom of the box
containing the hygiene bags (DDMMYYXX). Extended storage
time or exceeding the specified storage conditions may
compromise the performance of the adhesive tape and/or the
plastic material from which the hygiene bags are made.
Disposal Observe relevant national requirements.
PATIENT CONTACTING PARTS
Part type: Type of contact: Contact duration:
Imaging plate Mucosal membrane <5 min
Disposable cover for
imaging plate
Mucosal membrane <5 min

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KaVo SCAN EXAM and is the answer not in the manual?

KaVo SCAN EXAM Specifications

General IconGeneral
TypeIntraoral Scanner
ResolutionHigh
Imaging Technology3D
ConnectivityUSB
Software CompatibilityKaVo Dental Design, exocad

Related product manuals