GB - 19
KEB COMBICONTROL
The following particularities must be observed:
• Access is possible only to les in the root directory.
• Long le names to 32 characters are possible. For COMPACT II up to 60 cha-
racters.
• Reading takes place with high speed.
• Writing occurs at a slow rate, because the ash must be programmed here. New les
are rst created and stored in RAM. When closing the le, the data are stored in the
background to the ash.
• COMPACT Data are not physically deleted. First they are internal marked as
deleted. Thus the available memory capacity decreases. Format and
clear can be activated with parameter FI.07 (can also be started by
the IEC control program with the function "OdWrite").
• COMPACT II Data are automatically deleted in the background and assigned again
as free memory space.Parameter FI.07 has no function here.