EasyManua.ls Logo

KEB C6-COMPACT - Technical data

KEB C6-COMPACT
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB - 5
KEB COMBICONTROL
1.4 Unitidentication
C6 Material number Description
Compact
00C6BA1-(x)A(y)0 4DI/4DO
COMPACT II
00C6BD1-(x)C(y)0 4DI/4DO
(x) = eldbus module: A = no, B = PROFIBUS slave, C = CAN, D = INTERBUS slave
(y) = soft option: A = no, B = soft motion
Examples:
00C6BA1-AAB0 C6-Compact 4DI/4DO + soft motion
00C6BA1-BAB0 C6-Compact 4DI/4DO + PROFIBUS slave + soft motion
00C6BA1-CAA0 C6-Compact 4DI/4DO + CAN
00C6BA1-DAA0 C6-Compact 4DI/4DO + INTERBUS slave
00C6BD1-ACA0 C6-Compact II 4DI/4DO
00C6BD1-BCA0 C6-Compact II 4DI/4DO + PROFIBUS Slave
00C6BD1-CCB0 C6-Compact II 4DI/4DO + CAN + Softmotion
1.5 Technical data
General
Dimensions (HxBxT) 125 x 44 x 144 mm
Weight approx. 260 g
Installation method 35 mm Mounting rail
Grounding via terminal strip or plug-in contact
Protective system (EN 60529): IP20
Operation temperature -10…45 °C (14…113 °F)
Storage temperature -25…70 °C (-13…158 °F)
Climatic category (EN 60721-3-3): 3K3
Environment (IEC 664-1) Pollution degree 2
Control
Operating voltage control (US) 18…30 V DC ±0 %
Power input control 3 W max.
Digital inputs/outputs
Wiring system cage-clamp terminals
Operating voltage inputs/outputs (UM) 18…30 V DC ±0 %
Output current max. 0.7 A per channel, short-circuit proof, free-
wheeling diode integrated
Input voltage/current according to IEC 61131-2 Type 1

Related product manuals