CP-Parameterdenition
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 7.16 - 7
7
The calculation mode, the decimal places as well as the units indicated in KEB COMBIVIS are set with ud.21.
The parameter is bit-coded and set-programmable. It is adjustable in the range of 0...1791.
Bit 12...15 Bit 11...8 Bit 7...6 Bit 5...0 ud.21
- - - see table 1 unit
- - see table 2 - Calculation mode
- see table 3 - - Representation
free - - - -
Table 1 Unit (Bit 0...5)
Value unit Value unit Value unit Value unit
0 no 16 km/h 32 K 48 lbin
1 mm 17 rpm 33
m
W
49 in/s
2 cm 18 Hz 34
W
50 ft/s
3 M 19 kHz 35
k
W
51 ft/min
4 km 20 mV 36 inc 52 ft/s²
5 g 21 V 37 % 53 ft/s³
6 kg 22 kV 38 KWh 54 MPH
7 us 23 mW 39 mH 55 KP
8 ms 24 W 40 - 56 psi
9 s 25 kW 41 - 57 °F
10 h 26 VA 42 In 58 -
11 Nm 27 kVA 43 ft 59 -
12 kNm 28 mA 44 yd 60 -
13 m/s 29 A 45 oz 61 -
14 m/s
2
30 kA 46 lb 62 -
15 m/s
3
31 °C 47 lbft 63 -
Table 2 Calculation mode (Bit 6...7)
Value Function
0
(selected parameter + ud.20) x
ud.19
= CP.xx
———
ud.18
64
ud.19
= CP.xx
———————————————————
(selected parameter + ud.20) x ud.18
- free
The unstandardized value is always used for the „selected parameter“!