Functional DescriptionDigital In- and Outputs
t
t
t
t
t
1ms
t
t
t
Edge-active or static Strobe?
As a standard the Strobe is edge-active, i.e. the input conditions on the Strobe input
are accepted with rising edge and maintained until the next edge. For some applications
it is sensible to use the Strobe in a manner of a gate function. In that case the Strobe
signal is static, i.e. the input signals are accepted for as long as the Strobe signal is
set (or for as long as the gate is open).
di.7 Strobe-mode
Fig. 6.3.8.a Edge-active Strobe (di.7=0)
Fig. 6.3.8.b Static Strobe Mode 1 (di.7=1)
Signal at
terminals
Strobe input
Input status
Scanning grid
(acceptance upon
rising edge)
Strobe input
Resulting
Strobe signal
Signal at
terminals
Input status
Parameter Setting range Function
di.7 0 edge-active Strobe (default)
1 static strobe - frooze if strobe is not active
2 static strobe - only active at active strobe
t
t
t
Signal at
terminals
Strobe input
Input status
Fig. 6.3.8.c Static Strobe Mode 2 (di.7=2)

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals