EasyManua.ls Logo

KEB COMBIVERT F5 Servo

KEB COMBIVERT F5 Servo
378 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
411
KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional DesriptionSetpoint- and Ramp Adjustment
6
Fixed-value rotation direction
source (oP.18)
With oP.18 it is defined how the direction of rotation is determined in case of active
fixed value. The function and the value range correspond to oP.1.
oP.18 Rotation direction source for fixed values
0 digital via oP.2; setpoint 0-limited
1 digital via oP.2; setpoint absolute
2 terminal strip F/R; setpoint 0-limited
3 terminal strip F/R; setpoint absolute
4 terminal strip Run/Stop; setpoint 0-limited
5 terminal strip Run/Stop; setpoint absolute
6 setpoint-dependent with LS-recognition
7 setpoint-dependent without LS-recognition
8 control word SY.50; 0-limited
9 control word SY.50; 0-absolute
Fixed value input selection 1 and 2
(oP.19; oP.20)
Fixed value 1...3
(oP.21, oP.22, oP.23)
The three fixed values oP.21...23 are set-programmable and can be adjusted in the
range of -4000...4000 rpm.
Bit -No. Decimal value Input Terminal
0 1 ST (Prog. input ÑControl release/Resetì) X2A.16
1 2 RST (Prog. input ÑResetì) X2A.17
2 4 F (Prog. input ÑForwardì) X2A.14
3 8 R (Prog. input ÑReverseì) X2A.15
4 16 I1 (Prog. input 1) X2A.10
5 32 I2 (Prog. input 2) X2A.11
6 64 I3 (Prog. input 3) X2A.12
7 128 I4 (Prog. input 4) X2A.13
8 256 IA (Internal input A) none
9 512 IB (Internal input B) none
10 1024 IC (Internal input C) none
11 2048 ID (Internal input D) none

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Related product manuals