6 9
KEB COMBIVERT F5
26
Name: Basis
04.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All rights reserved
Functional Description Special Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Used Parameters
Pn.44 042Ch - 0 511 1 0 -
Pn.45 042Dh - - 200 V 800 V 1 V 290/500 V dep. of the voltage class
Pn.46 042Eh - - 50 % 90 % 1 % 80 % -
Pn.47 042Fh - - 0,0 % 100,0 % 0,1 % 0 % only F5-G/B
Pn.48 0430h - - 0 Hz 400 Hz 0,0125 Hz 0 Hz only F5-G/B
0430h - - 0 min
-1
4000 min
-1
0,125 min
-1
0 min
-1
only F5-M ; dep.on ud.2
Pn.50 0432h - - 200 V 800 V 1 V 290/500 V dep. of the voltage class
Pn.51 0433h - - 0 32767 1 128 (512) only F5-G; F5-M; (F5-B)
Pn.52 0434h - - 0,00 s 100,00 s 0,01 s 0,00 s -
Pn.53 0435h - - 0 32767 1 800 (50) only F5-G; (F5-B)
Pn.54 0436h - - 0 32767 1 800 (50) only F5-G; (F5-B)
Pn.55 0437h - - 0 32767 1 0 only F5-G/B
Pn.56 0438h - - 0 % 800 % 1 % 100 % only F5-G/B
Pn.57 0439h - - 0 32767 1 5 only F5-G; F5-M