KEB COMBIVERT F5
28
Name: Basis
04.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All rights reserved
Functional Description Special Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Used Parameters
oP.44 032Ch - 06310-
oP.45 032Dh - - 0,00 % 100,00 % 0,01 % 0,00 % -
oP.46 032Eh - - 0,00 s 20,00 s 0,01 s 10,00 s -
oP.47 032Fh - - 0,00 s 20,00 s 0,01 s 10,00 s -
oP.48 0330h - - 0,00 s 20,00 s 0,01 s 10,00 s -
Wobbel generator
Acceleration time (oP.47)
Deceleration time(oP.48)
With oP.47 the acceleration time and with oP.48 the deceleration is adjusted in each
case within the range of 0...20.00 s. Together the two parameters result in the period
duration of the wobbel period.
6.9.7.b Acceleration and deceleration times of the wobbel generator
f
t
f
set
oP.47 oP.48