CP - ParameterOperation
4
3
KEB COMBIVERT F5-M / S16
Name: Basis
17.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2003
All Rights reserved
Defines the time needed to decelerate from 1000 to 0 rpm. The actual deceleration
time is proportional to the speed change ( n). At a deceleration time of -0,01 the
value from CP.25 is used (Display: Ñ=Accì)!
Adjustment range: -1; 0,00...300,00 s
Resolution: 0,01 s
Factory setting: 5,00 s
Deceleration time forward
n speed change
t deceleration for n
t [s]
CP.26
n [rpm]
1000
800
300
0
0,5 1 1,5 2
t
n
Example:
The drive should decelerate from 800 rpm to 300 rpm in 1 s.
n = 800 rpm - 300 rpm = 500 rpm
t = 1 s
t1 s
CP.26 = ññññ x 1000 rpm = ññññññññ x 1000 rpm = 2 s
n 500 rpm