Parameter
5
113
KEB COMBIVERT F5-G / C / B
Name: Basis
10.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Parameter Adr. Control Properties min. max. Step default [?] see on Page
5
uf 0 rated frequency 05 00 B C g G M - A - P - V 0 400 0,0125 50 Hz 6.5.4
uf 1 boost 05 01 B C g G M - A - P - - 0,0 25,5 0,1 2,0 % 6.5.4
uf 2 add. frequency 05 02 B C g G M - A - P - V -1 400 0,0125 0:off Hz 6.5.4
uf 3 add. voltage 05 03 B C g G M - A - P - - 0,0 100,0 0,1 0,0 % 6.5.4
uf 4 delta boost 05 04 B C g G M - A - P - - 0,0 25,5 0,1 0,0 % 6.5.4
uf 5 delta boost time 0505 B C g G M - A - P - - 0,00 10,00 0,01 0,00 s 6.5.4
uf 6 energy saving mode 05 06 B C g G M - A - P - - 0 7 1 0 - 6.9.5
uf 7 energy saving factor 05 07 B C g G M - A - P - - 0,0 130,0 0,1 70,0 % 6.9.5
uf 8 energy saving input sel. 05 08 B C g G M - A - - E - 0 4095 1 0 - 6.9.5, 6.3.8
uf 9 voltage stabilisation 0509 B C g G M - - - P E - 1 650:off 1 650:off V 6.5.5
uf 10 max. voltage mode 05 0A - C - G M - A - P - - 0 3 1 0 - 6.5.6
uf 10 max. voltage mode 05 0A B - g -----P-- 0 2 1 0 - 6.5.6
uf 11 carrier frequency 05 0B B - g G M S A - P E - 0 LTK 1 LTK - 6.5.6
uf 12 base block time 05 0C B - g G M S A R - - - LTK LTK 0,01 LTK s 6.7.9
uf 13 base block voltage level 05 0D B - g G M S A R - - - LTK LTK 1 LTK % 6.7.9
uf 15 hardw. curr. lim. mode 050F - - - G M S A ---- 0 2 1 1 - 6.7.3
uf 15 hardw. curr. lim. mode 050F B - g -------- 0 1 1 1 - 6.7.3
uf 16 autoboost configuation 05 10 B - g G - - A - P - - 0 3 1 0 - 6.11.4
uf 17 autoboost gain 0511 B C g G - - A - P - - 0,00 2,50 0,01 1,20 - 6.11.4
uf 18 deadtime comp. mode 05 12 B C g G M - - ---- 0 1 1 1 - 6.7.9
uf 19 volt.stab.PT1-timeconst. 05 13 - - - G - - A ---- 0 10 1 0 - 6.5.5
uf 20 KI Offset-Control 0514 - - --------- 0 32767 1 50 -