6
6
17
KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional DesriptionOperating and Unit Data
Adr.
min max
default
0209h
ru. 9 Encoder 1 speed
0,125
rpm -
4000-4000
The displayed speed corresponds to the actual speed measured at the encoder input 1.
!ud.2!
!ud.2!
Adr.
min max
default
020Ah
ru.10 Encoder 2 speed
0,125
rpm
-
4000-4000
The displayed speed corresponds to the actual speed measured at the encoder input 2.
!ud.2!
!ud.2!
Adr.
min max
default
020Bh
ru.11 Set torque display
0,01
Nm
-
10000
-10000
The displayed value corresponds to the current set torque .
!ud.2!
Adr.
min max
default
020Ch
ru.12 Actual torque display
0,01
Nm
-
10000
-10000
The displayed value corresponds to the current actual torque.
!ud.2!
Adr.
min max
default
0207h
ru. 7 Actual value display
0,125
rpm
-
4000-4000
The displayed actual speed corresponds to the adjusted encoder input 1 or 2 by cS.1.
!ud.2!