X8 MIG WELDER 2.2 System structure
12. Strain relief holder
Indicator panel
1. Power indicator
The LED is green when the unit is on.
2. Voltage Reduction Device (VRD) indicator
The LED is green when VRD is switched on and the no-load voltage is under 35 V.
The LED blinks red when VRD is switched on and the no-load voltage is above 35 V.
The LED is off when VRD is switched off or during welding.
Note:
VRD is in use with MMA and Gouging modes only.
3. Overheat indicator
The LED is yellow when the unit is overheating.
Caution:
If the power source overheats, a thermal cutoff switches the unit off and does not allow it to be
used until it has cooled down.
4. Kemppi cloud connection
The LED is blue when the wire feeder or power source is connected to Kemppi cloud services.
The LED blinks blue when the wire feeder or power source is connecting to Kemppi cloud services.
5. Coolant level warning
The LED is yellow when the coolant level is too low.
6. Coolant temperature warning
The LED is yellow when the cooler is overheating.
Caution:
OPERATING MANUAL | EN 13
©