X8 MIG WELDER 2.6 Maintenance
Problem Recommended actions
High spatter volume
• Check the welding parameter values and welding procedure.
• Check the gas type and flow.
• Check the polarity of the gun/electrode.
• Check that the filler wire is correct for the current application.
2.5.1 Error codes
Control Pad
In error situations, Control Pad displays the number and title of the error, a description of the possible cause
(Reasons) and the Actions to fix the error. Go to View > Error log to see the error history.
Wire feeder control panel
The wire feeder control panel displays the number and title of the error.
Gun remote control display
The gun remote control display does not display the error code, just an error/warning symbol. Check the
Control Pad or Wire feeder control panel to see more information.
Symbol in gun remote control display Meaning
System warning. The warning concerns an error in
the system, for example, low liquid level. The symbol
first blinks for 10 seconds, then stays solid.
Welding is enabled even though the symbol is
displayed.
WPS warning. One of the most essential welding
parameters has been adjusted beyond the limits
of the WPS in use. The parameter in question is
displayed in red.
Welding is enabled even though the symbol is
displayed.
System error. Welding is disabled.
2.6 Maintenance
When considering and planning routine maintenance, consider the operating frequency of the welding
system and the working environment.
Correct operating of the welding machine and regular maintenance helps you avoid unnecessary downtime
and equipment failure.
OPERATING MANUAL | EN 170
©
KEMPPI | 2018-09-28