- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-4 Message Communication
3-38
3
Communicating with the GT2 Series
Group2
032AH
(810) to
033FH
(831)
Reserved for system
0340H
(832)
Group2 Entry
count
Indicates the number of items (entries) that can be
set in Group 2.
Parameter range: 20
RDINT
0341H
(833)
Bank 0 HIGH
setting
Indicates the bank 0 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W DINT
0342H
(834)
Bank 0 LOW
setting
Indicates the bank 0 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W DINT
0343H
(835)
Bank 0
preset value
Indicates the bank 0 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W DINT
0344H
(836)
Bank 0 HH
setting
*1
Indicates the bank 0 HH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 7.0000)
R/W DINT
0345H
(837)
Bank 0 LL
setting
*1
Indicates the bank 0 LL setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W DINT
0346H
(838)
Bank 1 HIGH
setting
Indicates the bank 1 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W DINT
0347H
(839)
Bank 1 LOW
setting
Indicates the bank 1 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W DINT
0348H
(840)
Bank 1
preset value
Indicates the bank 1 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W DINT
0349H
(841)
Bank 1 HH
setting
*1
Indicates the bank 1 HH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 7.0000)
R/W DINT
034AH
(842)
Bank 1 LL
setting
*1
Indicates the bank 1 LL setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W DINT
034BH
(843)
Bank 2 HIGH
setting
Indicates the bank 2 HIGH setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 5.0000)
R/W DINT
034CH
(844)
Bank 2 LOW
setting
Indicates the bank 2 LOW setting.
Parameter range:
-199.9999 to 199.9999 (initial value: 1.0000)
R/W DINT
034
DH
(84
5)
Bank 2
preset value
Indicates the bank 2 preset value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R/W DINT
Class
Attribute
ID
Name Description
Attribute
Data