3 Short-Range Comms & IoT Mode
3.2 Modulation Analysis Measurement
query the Y ref value of the third window
Preset Depends on trace data
State Saved Saved in instrument state
Min/Max -9.9E+37/9.9E+37
Annotation The reference value is displayed above the graticule with the title “Ref Value”
Ref Position
Positions the reference level at the top, center, or bottom of the Y Scale display.
Changing the reference position does not change the reference level value.
Remote
Command
:DISPlay:EVM:WINDow[1]|2|...|6:Y[:SCALe]:RPOSition TOP | CENTer | BOTTom
:DISPlay:EVM:WINDow[1]|2|...|6:Y[:SCALe]:RPOSition?
Example
:DISP:EVM:WIND3:Y:RPOS TOP
set the Y ref position of the third window to TOP
:DISP:EVM:WIND3:Y:RPOS?
query the Y ref position of the third window
Preset Depends on trace data
State Saved Saved in instrument state
Range Top | Ctr | Bot
X Width
Set the width of the X axis, which is displayed for the selected trace.
Remote Command
:DISPlay:EVM:WINDow[1]|2|...|6:X[:SCALe]:WIDTh <real>
:DISPlay:EVM:WINDow[1]|2|...|6:X[:SCALe]:WIDTh?
Example
:DISP:EVM:WIND3:X:WIDT 10e6
:DISP:EVM:WIND3:X:WIDT?
query the X width of the third window
Couplings If Auto Scaling is set to On, the X Width is determined by the trace data
Preset Depends on trace data
State Saved Yes
Min/Max -9.9E+37 / 9.9E+37
Burst Search State
This control enables you to turn burst search on or off.