EasyManua.ls Logo

Keysight N9000B - Ref Value; Ref Position

Keysight N9000B
2530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Short-Range Comms & IoT Mode
3.4 HRP UWB Demodulation Measurement
Example
:DISP:HUWB:WIND3:X:WIDT 10e6
set the X width of the third window to 10 MHz
:DISP:HUWB:WIND3:X:WIDT?
query the X width of the third window
Couplings If "Auto Scaling" on page 536 is ON, the X Width is determined by the trace data
Preset Depends on trace data
State Saved Yes
Min -9.9E+37
Max 9.9E+37
Ref Value
Controls the X value of the selected trace at the chosen X Reference Position.
Remote Command
:DISPlay:HUWB:WINDow[1]|2|3|4|8:X[:SCALe]:RLEVel <real>
:DISPlay:HUWB:WINDow[1]|2|3|4|8:X[:SCALe]:RLEVel?
Example
:DISP:HUWB:WIND4:TRAC:X:RLEV 10
:DISP:HUWB:WIND4:TRAC:X:RLEV?
Preset Depends on trace data
State Saved Saved in instrument state
Min -9.9E+37
Max 9.9E+37
Ref Position
Determines the position from which the X scaling is calculated for the selected
trace. It can be set to the left side, center, or right side of the grid.
Remote
Command
:DISPlay:HUWB:WINDow[1]|2|3|4|8:X[:SCALe]:RPOSition LEFT | CENTer | RIGHt
:DISPlay:HUWB:WINDow[1]|2|3|4|8:X[:SCALe]:RPOSition?
Example
:DISP:HUWB:WIND3:X:RPOS CENT
set the X ref position of the third window to CENT
:DISP:HUWB:WIND3:X:RPOS?
query the X ref position of the third window
Preset Depends on trace data
State Saved Yes
Range
LEFT|CENTer|RIGHt
Short Range Comms & IoT Mode User's &Programmer's Reference 535