Command Reference
Reflection Measurement Option Subsystem
136
Reflection Measurement Windows Select
[:SENSe]:CAT:WINDow
NONE|RECTangular|HAMMing|S3BLackman|S4BLackman
[:SENSe]:CAT:WINDow?
This command toggles the measurement window between
Rectangular Window, Hamming Window, 3- Sample Blackman
Window and 4- Sample Blackman Window.
Range: NONE, RECTangular, HAMMing, S3BLackman, S4BLackman
Example: :CAT:WINDow RECT
Key access: Meas > More 1 of 2 > Window
Reflection Measurement Start Frequency
[:SENSe]:CAT:FREQuency:STARt <freq>
[:SENSe]:CAT:FREQuency:STARt?
Use this command to define the start frequency of reflection
measurement.
Range: 5 MHz to 7 GHz
Example: :CAT:FREQuency:STARt 200 MHz
Key access: Freq > Start Frequency
Reflection Measurement Stop Frequency
[:SENSe]:CAT:FREQuency:STOP <freq>
[:SENSe]:CAT:FREQuency:STOP?
Use this command to define the stop frequency of reflection
measurement.
Range: 5 MHz to 7 GHz
Example: :CAT:FREQuency:STOP 1 GHz
Key access: Freq > Stop Frequency