155
Command Reference
Channel Scanner Option Subsystem
Set Scan Channel For Top N Sweep By Signal Standard
:CHSCanner:EDIT:TOP:STD <value>
:CHSCanner:EDIT:TOP:STD?
This command defines the signal standard for Top N sweep
method.
Example: :CHSCanner:EDIT:TOP:STD “d:/CDMA-AWS_DL.STD”
Key access: Meas > Range Edit > Edit Method Std > Signal Std
Set Scan Channel Range For Top N Sweep By Signal
Standard
:CHSCanner:EDIT:TOP:STD:RANGe <value>,<value>
:CHSCanner:EDIT:TOP:STD:RANGe?
This command specify scan channel range number for Top N
sweep mode. The signal standard should defined before this
operation.
Example: :CHSCanner:EDIT:TOP:STD:RANGe 10,100
Key access: Meas > Range Edit > Edit Method Std > Signal Std, then >Begin Chn,
> End Chn
Set Custom Scan Channel For Top N Sweep
:CHSCanner:EDIT:TOP:CUSTom <start freq>,<freq
step>,<bandwidth>,<ch. number>
:CHSCanner:EDIT:TOP:CUSTom?
This command specify the customer scan channels for Top N
Sweep. Need to input the start frequency, bandwidth of each
channel and channel number.
Example: :CHSCanner:EDIT:TOP:CUSTom
10000000,1000000,10000,100
Key access: Meas > Range Edit > Edit Method Custom
Set Start Frequency For Custom Scan Channel For Top N
Sweep
:CHSCanner:EDIT:TOP:CUSTom:STARt <value>

Table of Contents