Command Reference
Demodulation Option Subsystem
190
FSK Symbol Rate
[:SENSe]:DMA:RADio:STANdard:SRATe <sps>
[:SENSe]:DMA:RADio:STANdard:SRATe?
Use this command to specify symbol rate of ASK
demodulation analysis.
Range: 100 sps to 100 ksps
Example: :DMA:RADio:STANdard:SRATe 2ksps
Key access: Meas > Symbol Rate
FSK Measurement Filter
[:SENSe]:DMA:RADio:STANdard:FILTer:MEASurement
NONE|RNYQuist|NYQuist|GAUSsian
[:SENSe]:DMA:RADio:STANdard:FILTer:MEASurement?
Use this command to set the measurement filter of FSK
demodulation analysis.
Range: RNYQuist, NYQuist, GAUSsian, NONE
Example: :DMA:RADio:STANdard:FILTer:MEASurement RNYQuist
Key access: Meas > Filter Setup > Meas Filter
FSK Reference Filter
[:SENSe]:DMA:RADio:STANdard:FILTer:REFerence
RNYQuist|NYQuist|GAUSsian|NONE
[:SENSe]:DMA:RADio:STANdard:FILTer:REFerence?
Use this command to specify reference filter of FSK
demodulation analysis.
Range: RNYQuist, NYQuist, GAUSsian, NONE
Example: :DMA:RADio:STANdard:FILTer:REFerence RNYQuist
Key access: Meas > Filter Setup > Ref Filter