72 User’s Manual PLZ-5W
Advanced Functions | Synchronized Operation
Synchronizing the resuming of sequences
A sequence will stop at a step with Wait (pre) set to MSync (p.80).
The resuming of a paused sequence (trigger wait) can be synchronized on multiple synchronized PLZ-
5Ws. To synchronize, you first need to create a sequence (p.74).
1
Press Sequence, Transient, and then Initiate on all PLZ-5Ws to be synchronized.
The sequence is executed.
2
Wait for the sequence on all synchronized PLZ-5W to be paused.
The sequence pauses before executing a step with Wait (pre) set to MSync, and “MSync” appears
in the sub-function area.
3
Press MSync on any of the synchronized PLZ-5Ws.
The sequence resumes simultaneously on all synchronized PLZ-5Ws.
Aborting synchronized operation
The synchronized operation setting is cleared when you remove the LAN cables.