Installation and initial operation
DF10 with
upgrade kit
faulty:
» Plug connection not
connected to the outrigger.
» Defective cable, solenoid coil
» Connect plug connection.
» Repair cable, solenoid coil or
valve,
replace if necessary.
» No electrical contact
on the valve.
» Check valve connector under the
covering
» Oil flow rate not
sufficient.
» Optimise dimensioning of the
hoses.
» Check hydraulic connections
and couplers for
rotating -
despite activation
of tilt or
CSP
» Pressure Line and
Tank connections were reversed.
» Note
label marking.
» Correctly connect
hoses of the carrier.
» Malfunction
on the quick
coupler.
CSP
faulty:
» Plug connection not
connected to the outrigger.
» Defective cable, solenoid coil
» Connect plug connection.
» Repair cable, solenoid coil or
valve,
replace if necessary.
» No electrical contact
on the valve.
» Check valve connector under the
covering
» Faulty configuration
of the control system.
» Configure control system.
DF4
faulty:
» Plug connection not
connected to the outrigger.
» Defective cable, solenoid coil
» Connect plug connection.
» Repair cable, solenoid coil or
valve,
replace if necessary.
» No electrical contact
on the valve.
» Check valve connector under the
covering
» Faulty configuration
of the control system.
» Configure control system.
DF10
» Oil flow rate not
sufficient.
» Optimise dimensioning of the
hoses.
» Check hydraulic connections
and couplers for
» Check
carrier installation.
DF10 with
upgrade kit
» Oil flow rate not
sufficient.
» Optimise dimensioning of the
hoses.
» Check hydraulic connections
and couplers for
» Check
carrier installation.