KLR.950 Revision: 2023-10-06
Serial numbers: 3008 – beyond
KLR.00001 – beyond
24
5.7.1.2: Interlock with speed given by the bagger
1. Press the bagger configuration button.
Now on this page, the interlock can be configure.
By now, the ON/OFF and speed adjustment is no longer accessible.
Ratio forced in decimal
(must be greater to 0)
Re
a
l number of pulses
the bagger is currently
sending to the KLR.950
Enter in the black fields
the desired ratio to be
applied. Press CALC.
Check to use
speed
given by the bagger.
Final speed
request to
the KLR.950
Use one or the other
.
Sending calculation to
KLR.950 controller
Add a
tolerance to
soften the
variations.

Table of Contents