Additional Service Procedures
SM1399-1 – 19JUN06 73
[14] If the calibrations are not successful, do:
Failure Description Cause Action
“W/O Shutter K” No SHUTTER calibration. Do the procedures:
1. “
MCU BOARD/LENS AY - “Shutter Delay”” on
Page 36
2. “Doing a Calibration of the Test Equipment” on
Page 72 again
“Memory Fail” Software “script” failure Do the procedure “
Doing a Calibration of the Test
Equipment” on Page 72 again.
“ISO Cal Fail” Environment variation 1. Check the settings and environment variations.
2. Do the procedure “
Doing a Calibration of the Test
Equipment” on Page 72 again.