66 A-61550 July 2008
Known limitations -
Linux
Issue: The number of pages value is not communicated to the SANE
driver. The number of pages is just presented as a “tally” that the
XSANE application uses to count the number of images that are
captured.
Solution: Set the Number of Pages field to a number that is larger than
the number of images that will be captured in a batch.
Issue: The LED on the scanner is red even though the scanner is
securely connected to the PC.
Solution: The LED will remain a steady red until your application
connects to the scanner.
Issue: If the following Communications error is displayed when you
select a scanner after initially installing Linux drivers on Fedora 7,
Please check to make sure the scanner has powered up successfully
and the cable is securely attached to both the PC and the scanner. If
you are still having a problem, power down the scanner, then power up
the scanner, wait for it to finish initializing and try again.
follow the steps in the “Solution” below:
Solution: Before checking cable connections and performing the
power down sequence:
1. Click OK on the message.
2. Select System>Administration>SELinux Management.
3. Enter your root/superuser password. The SELinux Administration
screen will be displayed.
4. Select Permissive from the System Default Enforcing mode drop-
down list.
5. Select Permissive from the Current Enforcing mode drop-down list.
6. Close the SELinux Administration screen and try again.