- 28 -
KD 625-2 Workshop Manual_cod. ED0053029380_1° ed_ rev. 00
4
5
6
8
9
7
Clogging indicator
Components:
1 Reset button
2 Transparent indicator
Note: Indicator is calibrated at 600÷650 mm column of water.
Disassembly / Reassembly
Exhaust manifold
Check that the inside is clean.
To avoid ange breakage check that heads are in line before tightening
nuts.
Replace gaskets.
Tighten nuts at 20 Nm.
MANIFOLDS, INTAKE/EXHAUST
Intake manifold
To avoid ange breakage check that heads are in line before tightening
nuts.
Check ange surface for warpage and correct if necessary.
Replace gaskets.
Tighten nuts at 25 Nm.
Note: In case of low temperature starting we can supply a manifold
with possibility of tting a glow plug with air preheating.
Oil vapour separator
Fitted on engines with dry air cleaner.
Screw it out of the air conveyor support, carefully wash with gasoline
inside and blow out with compressed air.
When retting replace the copper gasket and connect the oil vapour
separator with intake manifold by means of the special rubber hose.