Page #45 background imageLoading...
Page #45 background image
- 45 -
KD 625-2 Workshop Manual_cod. ED0053029380_1° ed_ rev. 00
A
069.14÷049.14
580.0÷040.0 061.0
C
520.24÷000.24
B
069.72÷049.72
580.0÷040.0 051.0
D
520.82÷000.82
4
82
84
83
81
I-A
020.0÷020.0- 30.0
M-B
020.0÷810.0- 30.0
O-C
030.0÷010.0- 40.0
Disassembly / Reassembly
CAMSHAFT
How to measure camshaft journals and housings
Use an inside micrometer gauge for housings and an outside micrometer
gauge for journals.
Clearance
(mm)
Limit value
(mm)
Dimensions
(mm)
Ref.
Dimensions of camshaft journals and housings
Crankshaft end play
When retting crankshaft check end play by means of a thickness gau-
ge; this value should be 0.08 ÷ 0.38 mm and can be set by changing
the thickness of gasket A which is located on the ywheel-side main
bearings.
Gaskets with thickness of 0.30 and 0.50 mm can be supplied.
Important
Replace the main bearings 1 and 3 (Fig. 79) if the axial clearance
value still turns out to be too high even with a seal having a smaller
thickness (g. 79).
Ref.
Clearance (mm) Limit value (mm)
Table “Clearance between main bearings and main bearing housings”