Kramer Electronics Ltd.
KIT-400 Operating and Controlling KIT-400
22
Uploading EDID from an External File
To select the EDID from an external file:
1. Upload the EDID file to a memory stick.
The EDID file name should be USER_EDID1.bin or USER_EDID2.
2. On the front panel press MENU. The OSD menu appears.
3. Click ADVANCED and select EDID UPLOAD.
4. Select USER EDID.
The external EDID file is saved to the device.
Defining the TOGGLE PIN on KIT-400R
KIT-400R enables defining the TOGGLE pin
functionality. For example, you can define
this pin to select one of the 2 inputs, turn the display on or off and so on.
To define the TOGGLE PIN functionality:
1. On the front panel press MENU. The menu appears.
2. Click Toggle Pin and define the TOGGLE pin functionality according to the information
in the following table:
Menu Item
Function
EDGE
Set for edge triggering (momentary connection):
Toggles between switching the display on and off (using CEC commands)
each time the TOGL pin is momentarily connected to ground.
ON
Sends a CEC signal to turn the display ON when the TOGL pin is shorted
to ground.
Select ON when using together with an occupancy sensor that is set
up to short the sensor wire to ground when detecting the presence of
people in the room (see Connecting an Occupancy Sensor to the
TOGL Pin on page 11).
OFF
Sends a CEC signal to turn the display OFF when the TOGL pin is shorted
to the ground.
Select OFF when using together with an occupancy sensor that is set
up to short the sensor wire to ground when detecting no people in the
room (see Connecting an Occupancy Sensor to the TOGL Pin
on page 11).
INPUT
SELECT
Set to select between inputs (HDBT or HDMI).
TOGGLE pin functionality is defined.