VS-44H2A Technical Specifications
35
Technical Specifications
Inputs
4 HDMI
On female HDMI connectors
Outputs
4 HDMI
On female HDMI connectors
Ports
1 USB
On a mini USB connector
1 RS-232
On a 3-pin terminal block
1 Ethernet
On an RJ-45 female connector
1 USB
On a female USB-A connector for
powering another device
Video
Max. Resolution
4K@60Hz (4:2:0) and 4K@30Hz (4:4:4)
Compliance
Supports HDMI and HDCP 1.4
Control
Front Panel
Front panel buttons
7-segment display
Power
Consumption
42VA
Source
100-240V AC, 50/60Hz
Regulatory
Compliance
Safety
CE, FCC
Environmental
RoHs, WEEE
Enclosure
Type
Aluminum
Cooling
Fan
Environmental
Conditions
Operating Temperature
to +40°C (32° to 104°F)
Storage Temperature
-4to +70°C (-4 to 158°F)
Humidity
10% to 90%, RH non-condensing
General
Net Dimensions (W, D, H)
19", 7.2", 1U, rack mountable
Shipping Dimensions (W, D, H)
52.5cm x 33cm x 10.7cm
(20.7” x 13” x 4.2”)
Net Weight
1.9kg (4.2lbs) approx.
Shipping Weight
2.9kg (6.39lbs) approx.
Accessories
Included
Rack ears, power cord
Specifications are subject to change without notice at www.kramerav.com
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing
Administrator, Inc.
Default Communication Parameters
RS-232/Ethernet
Baud Rate:
115,200
Parity:
None
Data Bits:
8
Command Format:
ASCII Protocol 3000
Stop Bits:
1
Example (route video HDMI IN 2 to video HDMI OUT 4):
“#ROUTE 1,4,2”,0x0D
Ethernet Parameters
IP Address:
192.168.1.39
Default TCP Port #:
5000
Subnet Mask:
255.255.0.0
Default UDP Port #:
50000
Default Gateway:
192.168.0.1
Number of TCP ports:
8
Default username:
Admin
Number of web clients:
5
Default password:
Admin
Full Factory Reset
Front Panel Buttons:
Power off the device, press and hold the LOCK, EDID and STO buttons
simultaneously for about 3 seconds while powering the device, and then release.
Until all front panel buttons illuminate
Protocol 3000:
“#factorycommand.