Kramer Electronics Ltd.
VS-88H2A Protocol 3000
78
Function
Description
Syntax
Parameters/Attributes
Example
TUNNEL-
CTRL
LEGACY COMMAND.
Send an
asynchronous
command to a remote
Step-in equipment.
COMMAND
#TUNNEL-CTRLio_mode,io_index,cmd_name<CR>
FEEDBACK
None
io_mode Input/Output
0 Input
1 Output
io_index Number that indicates
the specific input or output port:
1-N (N= the total number of input or
output ports)
cmd_name Command to send to
the Step-in client
LEGACY COMMAND:
#TUNNEL-CTRL1,1,1<CR>
UART
Set com port
configuration.
If Serial is configured
when RS-485 is
selected, the RS-485
UART port
automatically changes.
The command is
backward compatible,
meaning that if the
extra parameters do
not exist, FW goes to.
RS-232.
Stop_bits 1.5 is only
relevant for 5
data_bits.
COMMAND
#UARTcom_id,baud_rate,data_bits,parity,stop_bits_mode,se
rial_type,485_term<CR>
FEEDBACK
~nn@UARTcom_id,baud_rate,data_bits,parity,stop_bits_mode
,serial_type,485_term<CR><LF>
com_id 1 to n (machine
dependent)
baud_rate 9600 - 115200
data_bits 5-8
parity Parity Type
0 No
1 Odd
2 Even
3 Mark
4 Space
stop_bits_mode 1/1.5/2
serial_type 232/485
0 232
1 485
485_term 485 termination state
0 disable
1 enable
(optional - this exists only when
serial_type is 485)
Set baud rate to 9600, 8 data
bits, parity to none and stop bit
to 1:
#UART9600,8,node,1<CR>
UART?
Get com port
configuration.
If Serial is configured
when RS-485 is
selected, the RS-485
UART port
automatically changes.
The command is
backward compatible,
meaning that if the
extra parameters do
not exist, FW goes to.
RS-232.
Stop_bits 1.5 is only
relevant for 5
data_bits.
COMMAND
#UART?com_id<CR>
FEEDBACK
~nn@UARTcom_id,baud_rate,data_bits,parity,stop_bits_mode
,serial_type,485_term<CR><LF>
com_id 1 to n (machine
dependent)
baud_rate 9600 - 115200
data_bits 5-8
parity Parity Type
0 No
1 Odd
2 Even
3 Mark
4 Space
stop_bits_mode 1/1.5/2
serial_type 232/485
0 232
1 485
485_term 485 termination state
0 disable
1 enable
(optional - this exists only when
serial_type is 485)
Set baud rate to 9600, 8 data
bits, parity to none and stop bit
to 1:
#UART1,9600,8,node,1<C
R>
VERSION?
Get firmware version
number.
COMMAND
#VERSION?<CR>
FEEDBACK
~nn@VERSIONfirmware_version<CR><LF>
firmware_version
XX.XX.XXXX where the digit groups
are: major.minor.build version
Get the device firmware
version number:
#VERSION?<CR>
VID
LEGACY COMMAND.
Set video switch state.
The GET
command identifies
input switching on
Step-in clients.
The SET command is
for remote input
switching on Step-in
clients (essentially via
by the Web).
This is a legacy
command. New Step-
in modules support the
ROUTE command.
COMMAND
#VIDin_id>out_id<CR>
FEEDBACK
~nn@VIDin_id>out_id<CR><LF>
in_id Indicates the ID of the
input:
1-n (n= the total number of inputs)
> Connection character between
in and out parameters
out_id Output number
* for all outputs
Switch IN 1 to OUT 3:
#VID1>3<CR>
VID?
LEGACY COMMAND.
Get video switch state.
The GET
command
identifies input
switching on
Step-in clients.
The SET
command is for
remote input
switching on
Step-in clients
(essentially via
by the Web).
This is a legacy
command. New Step-
in modules support the
ROUTE command.
COMMAND
#VID?out_id<CR>
FEEDBACK
~nn@VIDin_id>out_id<CR><LF>
in_id Indicates the ID of the
input:
1 HDMI IN 1
2 HDMI IN 2
3 HDMI IN 3
4 HDMI IN 4
5 HDMI IN 5
6 HDMI IN 6
7 HDMI IN 7
8 HDMI IN 8
> Connection character between
in and out parameters
out_id Output number:
1 HDMI OUT 1
2 HDMI OUT 2
3 HDMI OUT 3
4 HDMI OUT 4
5 HDMI OUT 5
6 HDMI OUT 6
7 HDMI OUT 7
8 HDMI OUT 8
Get video switch state:
#VID?2<CR>