6 Commissioning/Start-up/Shutdown
31 of 64
Etaline
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
Switch off the pump (set) immediately.
Eliminate the causes before returning the pump set to service.
ü The system piping has been cleaned.
ü The pump, suction line and inlet tank, if any, have been vented and primed with
the fluid to be pumped.
ü The lines for priming and venting have been closed.
CAUTION
Start-up against open discharge line
Motor overload!
Make sure the motor has sufficient power reserves.
Use a soft starter.
Use speed control.
1. Fully open the shut-off element in the suction head/suction lift line.
2. Close or slightly open the shut-off element in the discharge line.
3. Start up the motor.
4. Immediately after the pump has reached full rotational speed, slowly open the
shut-off element in the discharge line and adjust it to comply with the duty
point.
6.1.6 Shutdown
CAUTION
Heat build-up inside the pump
Damage to the shaft seal!
Depending on the type of installation, the pump set requires sufficient after-
run time – with the heat source switched off – until the fluid handled has
cooled down.
CAUTION
Backflow of fluid handled is not permitted
Motor or winding damage! Mechanical seal damage!
Close the shut-off elements.
ü The shut-off element in the suction line is and remains open.
1. Close the shut-off element in the discharge line.
2. Switch off the motor and make sure the pump set runs down smoothly to a
standstill.
NOTE
If the discharge line is equipped with a non-return or check valve, the shut-off
element may remain open provided that the system conditions and system
regulations are considered and observed.