16 ELECTRICAL SYSTEM
100
F03140-10
Main work
Check the battery voltage.
» Battery voltage: < 9 V
Do not charge the 12-V battery.
Replace the 12-V battery and dispose of the old 12-V
battery properly.
» If the specifications have been met:
Battery voltage: 9 V
Connect a battery charger to the 12-V battery. Switch
on the battery charger.
Guideline
The charging current, charging voltage, and charging
time must not be exceeded.
Maximum charging volt-
age
14.4 V
Maximum charging cur-
rent
3.0 A
Maximum charging time 24 h
Recharge the 12-V bat-
tery regularly when the
motorcycle is not being
used
6 months
Battery charger (58429074000)
These battery chargers test whether the 12-V battery
retains its voltage. It is also impossible to overcharge
the 12-V battery with these battery chargers. The
charging time may be longer at low temperatures.
These battery chargers are only suitable for lithium iron
phosphate batteries. Read the accompanying KTM Pow-
erParts instructions.
Info
Never remove cover
1
.
Finishing work
Install the 12-V battery. ( p. 98)
Lock the seat. ( p. 69)
16.4 Changing the fuses of individual electrical power consumers
Info
The fuse box containing the fuses for the individual power consumers is located under the seat, behind
the 12-V battery.
Preparatory work
Deactivate the vehicle. ( p. 43)
Fold the seat up. ( p. 69)
Remove the Powerpack HV. ( p. 108)
Mount the protection cap. ( p. 71)

Table of Contents