54 / 125 Issued: 16.03.2016 Version: MA KR 300 470-2 PA V5
KR 300-2 PA, KR 470-2 PA
To ensure that the anchor forces are safely transmitted to the foundation, ob-
serve the dimensions for concrete foundations specified in the following illus-
tration (>>> Fig. 6-3 ).
Fig. 6-2: Mounting base, dimensioned drawing
Fig. 6-3: Cross-section of foundation 175 mm
1 Bedplate
2 Chemical anchors (resin-bonded anchors) with Dynamic Set
3 Concrete foundation