55 / 125Issued: 16.03.2016 Version: MA KR 300 470-2 PA V5
6 Planning
6.2 Mounting base for 200 mm concrete thickness
Description The mounting base for 200 mm concrete thickness (>>> Fig. 6-4 ) is used
when the robot is fastened to the floor, i.e. directly on a concrete foundation
with a thickness of at least 200 mm.
The mounting base with centering consists of:
Bedplates
Chemical anchors (resin-bonded anchors) with Dynamic Set
Fastening elements
This mounting variant requires a level and smooth surface on a concrete foun-
dation with adequate load bearing capacity. The concrete foundation must be
able to accommodate the forces occurring during operation. There must be no
layers of insulation or screed between the bedplates and the concrete founda-
tion.
The minimum dimensions must be observed.
Grade of concrete
for foundations
When producing foundations from concrete, observe the load-bearing capac-
ity of the ground and the country-specific construction regulations. There must
be no layers of insulation or screed between the bedplates and the concrete
foundation. The quality of the concrete must meet the requirements of the fol-
lowing standard:
C20/25 according to DIN EN 206-1:2001/DIN 1045-2:2008
Dimensioned
drawing
The following illustrations provide all the necessary information on the mount-
ing base, together with the required foundation data.
Fig. 6-4: Mounting base 200 mm
1 Bedplate 3 Pin with Allen screw
2 Hexagon bolt 4 Chemical anchors with Dy-
namic Set