2H9
1-5-39
1-5-9 PWBs
(1) Detaching and refitting the control PWB
Procedure
1. Remove the right cover (See page 1-5-3).
2. Remove the five connectors from the scan-
ner PWB.
3. Remove nineteen connectors and two FFCs
form the control PWB.
4. Remove the wires from the clamp.
Figure 1-5-59
Scanner PWB
Wires
Clamp
YC29YC28
YC6
YC8
YC7
(FFC)(FFC)
YC3
YC19
YC30
YC23
YC25 YC17
YC13
YC16 YC20
YC27
YC21 YC18
YC24
YC10
YC26
YC9
YC101
YC109
YC108YC104
YC105
Connectors
FFCsConnectors
Control PWB
Scanner PWB
Control PWB