2H9-1
1-3-3
Operation
panel and
support
equipment
U200 Turning all LEDs on -
U203 Checking DP operation -
U207 Checking the operation panel keys -
U223 Operation panel lock -
U243 Checking the operation of the DP motor solenoids and clutch -
U244 Checking the DP sensors -
Mode setting U250 Setting the maintenance cycle 100000
*1
U251 Checking/clearing the maintenance count -
U252 Setting the destination -
U253 Switching between double and single counts Double count
U260 Selecting the timing for copy counting EJECT
*1
U265 Setting OEM purchaser code 0
U278 Setting the delivery date -
U285 Setting service status page ON
U332 Setting the size conversion factor 1.0
*1
U342 Setting the ejection restriction ON
*1
U343 Switching between duplex/simplex copy mode OFF
*1
U345 Setting the value for maintenance due indication 0
*1
Image
processing
U402 Adjusting margins of image printing 30/25/25/30
U403 Adjusting margins for scanning an original on the platen 2.0/2.0/2.0/5.0
U404 Adjusting margins for scanning an original from the DP 3.0/2.5/3.0/4.0
U407 Adjusting the leading edge registration for memory image
printing
0
U411 Adjusting the scanner automatically -
U425 Setting the target -
Others U901 Checking copy counts by paper feed locations -
U903 Checking/clearing the paper jam counts -
U904 Checking/clearing the service call counts -
U905 Checking/clearing counts by optional devices -
U908 Checking the total counter value -
U910 Clearing the black ratio data -
U911 Checking/clearing copy counts by paper sizes -
U917 Setting backup data reading/writing -
U920 Checking the copy counts -
U927 Clearing the all copy counts and machine life counts (one
time only)
-
U928 Checking machine life counts -
U942 Setting of deflection for feeding from DP 0/0
U969 Checking of toner area code -
U977 Data capture mode -
U991 Checking the scanner count -
U993 Outputting a VTC-PG pattern -
Section Item
No.
Content of maintenance item Initial
setting*