2H9-1
1-4-6
3200 Exposure lamp error
The exposure lamp is not turned on.
Defective FFC
between scanner
PWB (YC103) and
control PWB
(YC6), or improper
FFC insertion.
Reinsert the FFC. Also check for continuity
within the FFC. If none, remedy or replace
the FFC.
Defective FFC
between CCD
PWB (YC1) and
control PWB
(YC8).
Replase the image scanner unit (ISU) (See
page 1-5-21).
Defective harness
between CCD
PWB (YC3) and
inverter PWB
(YC101), or
improper connec-
tor insertion.
Reinsert the connector. Also check for conti-
nuity within the connector harness. If none,
remedy or replace the harness.
Defective harness
between inverter
PWB (YC102) and
exposure lamp, or
improper connec-
tor insertion.
Reinsert the connector. Also check for conti-
nuity within the connector harness. If none,
remedy or replace the harness.
Defective exposure
lamp.
Replace the exposure lamp (See page 1-5-
27).
Defective inverter
PWB.
Replace the inverter PWB (See page 1-5-
27).
Defective control
PWB.
Replace the control PWB (See page 1-5-
39).
3300 AGC error
After AGC, correct input is not obtained
at CCD.
Defective FFC
between CCD
PWB (YC1) and
control PWB
(YC8).
Replase the image scanner unit (ISU) (See
page 1-5-21).
Defective exposure
lamp.
Replace the exposure lamp (See page 1-5-
27).
Defective CCD
PWB.
Replace the CCD PWB.
Defective control
PWB.
Replace the control PWB (See page 1-5-
39).
Code Contents
Remarks
Causes Check procedures/corrective measures

Table of Contents