(5) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is not correct.
U067
(P. 1-6-48)
U065
(main scanning
direction)
U065
(auxiliary scanning
direction) (P. 1-6-46)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Also, perform (6) Adjusting magnification of the scanner in the auxiliary scanning direction (page 1-6-46) and (8)
Adjusting the scanner center line (page 1-6-48) after this adjustment.
Procedure
Original Copy
example
Copy
example 2
Figure 1-6-55
Enter maintenance mode.
Enter 065 using the copy exposure
adjustment keys or zoom +/- keys.
Yes
No
Start
End
Press the program key and the
machine enters the test copy mode.
Place an original and press
the start key to make a test copy.
Is the image correct?
Setting range: 25 +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
For copy example 1, increase the
value using the zoom (+) key.
For copy example 2, decrease the
value using the zoom () key.
Press the start key.
The new setting
is stored.
Select Exp. 1 (main scanning
direction) using the copy exposure
adjustment keys.
Press the start key.
Press the stop/clear key to
exit maintenance mode.