EasyManua.ls Logo

Kyocera KM-1650

Kyocera KM-1650
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2DA/2DB
1-5-33
(18)Image center does not align with
the original center.
Causes
1. Misadjusted center line of image printing.
2. Misadjusted scanner center line.
3. Original placed incorrectly.
Causes Check procedures/corrective measures
1. Misadjusted center line of image printing.
Readjust the center line of image printing (see page 1-6-18).
2. Misadjusted scanner center line.
Readjust the scanner center line (see page 1-6-36).
3. Original placed incorrectly.
Place the original correctly.

Table of Contents

Other manuals for Kyocera KM-1650

Related product manuals