2DA/2DB-1
1-6-49
(6) Detaching and refitting the fixing thermostat
Follow the procedure below to replace the fixing thermostat.
Procedure
1. Remove the fixing unit and separate the fix-
ing right unit and left unit (see pages 1-6-43,
45).
2. Remove the heat roller (see page 1-6-48).
3. Remove the two screws holding the fixing
thermostat and then the thermostat.
4. Replace the fixing thermostat and refit all
the removed parts.
Figure 1-6-88
(7) Detaching and refitting the fixing thermistor
Follow the procedure below to replace the fixing thermistor.
Procedure
1. Remove the fixing unit and separate the fix-
ing right unit and left unit (see pages 1-6-43,
45).
2. Remove the heat roller (see page 1-6-48).
3. Remove the screw holding the fixing ther-
mistor and then the thermistor.
4. Replace the fixing thermistor and refit all the
removed parts.
Figure 1-6-89
Fixing thermostat
Fixing thermistor