2DA/2DB-1
1-3-14
8. Press the duplex unit in the direction indi-
cated by the arrow to fit the claws into the
conveyer unit.
Figure 1-3-22-1
9. Hang the hook of the plate lock on the con-
veying unit and then turn the plate lock to fit
the hole to the claw of the duplex unit.
Figure 1-3-22-2
10. Secure the duplex unit with the two S tite
screws M3 x 06.
Figure 1-3-23
Claw
Claws
Duplex unit
Hook
Plate lock
Hole
Claw
Duplex unit
S tite screws
M3 x 06