2DA/2DB-3.0
1-4-3
High voltage U100 Checking the operation of main high voltage 132/60/50/10
U101 Setting high voltages
Developing bias
Transfer voltage
Separation voltage
27/45/22/45
166/177/37/35
1/35/42
U110 Checking/clearing the drum count -
Developing U130 Initial setting for the developer -
U144 Setting toner loading operation OFF
U157 Checking/clearing the developing drive time -
U158 Checking the developing count -
Fixing and
cleaning
U161 Setting the fixing control temperature
Primary stabilization fixing temperature
Secondary stabilization fixing temperature
Copying operation temperature 1
Copying operation temperature 2
Number of sheets for fixing control
Number of sheets for fixing control (thick paper)
140
160
170
180
5
20
U162 Stabilizing fixing forcibly -
U163 Resetting the fixing problem data -
U167 Checking/clearing fixing counts -
U199 Checking the fixing temperature -
Operation
panel and
support
equipment
U200 Turning all LEDs on -
U202 Setting the KMAS host monitoring system -
U203 Checking DP operation -
U204 Setting the presence or absence of a key card or key counter OFF
U207 Checking the operation panel keys -
U233 Setting the ejection limit of the job separator MODE0
U243 Checking the operation of the DP motors and solenoids -
U244 Checking the DP switches -
U245 Checking messages -
U246 Setting the finisher 4/4/4
U249 Checking the paper ejection to optional devices -
Mode setting U250 Setting the maintenance cycle 150000
U251 Checking/clearing the maintenance count -
U252 Setting the destination Japan
U253 Switching between double and single counts Double count
U254 Turning auto start function on/off ON
U258 Switching copy operation at toner empty detection Single mode
U260 Changing the copy count timing After ejection
U264 Setting the display order of the date Inch specifications:
MONTH-DATE-YEAR
Metric specifications:
DATE-MONTH-YEAR
U265 Setting OEM purchaser code -
U277 Setting auto application change time 30
U326 Setting the black line cleaning indication ON
U332 Setting the size conversion factor 1.0/1.0/1.0
U341 Specific paper feed location setting for printing function -
U342 Setting the ejection restriction ON
Section Item
No.
Content of maintenance item Initial
setting*
*Initial setting for executing maintenance item U020