2C9
1-5-27
Causes Check procedures/corrective measures
1. Misadjusted center line of image printing. Readjust the center line of image printing (see page 1-6-14).
2. Misadjusted scanner center line. Readjust the scanner center line (see page 1-6-31).
3. Original placed incorrectly. Place the original correctly.
(18)Image center does not
align with the original
center.
Causes
1. Misadjusted center line of image printing.
2. Misadjusted scanner center line.
3. Original placed incorrectly.