Maintenance
Description
item No.
2C9
1-4-42
Image mode LED (group No.) Copy exposure indicator Copy quantity display (count value)
9
10
11
12
13
Exp. 1 (lit) “-Lt” display the Letter size
Exp. 2 (lit)
First 3 digits of Letter size copy count
Exp. 3 (lit)
Last 3 digits of Letter size copy count
Exp. 4 (lit) Clearing the count (CLE)
Exp. 1 (lit) “-Lg” display the Legal size
Exp. 2 (lit)
First 3 digits of
Legal
size copy count
Exp. 3 (lit)
Last 3 digits of
Legal
size copy count
Exp. 4 (lit) Clearing the count (CLE)
Exp. 1 (lit) “-St” display the Statement size
Exp. 2 (lit)
First 3 digits of Statement size copy count
Exp. 3 (lit)
Last 3 digits of Statement size copy count
Exp. 4 (lit) Clearing the count (CLE)
Exp. 1 (lit) “-ot” display the other size
Exp. 2 (lit) First 3 digits of other size copy count
Exp. 3 (lit) Last 3 digits of other size copy count
Exp. 4 (lit) Clearing the count (CLE)
Exp. 1 (lit) Clearing all counts (CLE)
: Off : On : Flashing
U911
Clearing copy counts by paper size
1. Select the paper size to clear the count.
2. Display “CLE” using the copy exposure adjustment keys.
3. Press the start key. The count is cleared.
Clearing copy counts for all paper size
1. Select group 13.
2. Press the start key. The counts are cleared.
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
U927 Clearing accounting counter
Description
Clears the total count and the scanner count. The counts, however, can be cleared only one time. If either of the
total count or the scanner count exceeds 1,000, this mode cannot be run.
Purpose
To start the counters with value 0 when installing the machine.
Method
1. Press the start key. If the counters have been already cleared or either of the total counter or the scanner
counter exceeds 1,000, this mode cannot be run and “nG” is displayed.
2. Select “on” using the zoom +/– keys.
Display Operation
––– Canceling the clearing
on Executing the clearing
3. Press the start key. The accounting counter is cleared.
Completion
To exit this maintenance item without clearing the data, press the stop/clear key. The indication for selecting a