EasyManua.ls Logo

Kyocera TASKALFA 300I - Page 305

Kyocera TASKALFA 300I
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2K5
2-3-23
YC6 1 +5VSL O 5 V DC 5 V DC power output to HPSW
Connected
to the home
position
switch, origi-
nal detec-
tion switch
and original
size sensor
2 HPSWN I 0/5 V DC HPSW: On/Off
3 GND - - Ground
4 +5VSL O 5 V DC 5 V DC power output to ODSW
5 OPSWN I 0/5 V DC ODSW: On/Off
6 GND - - Ground
7 +5VSL O 5 V DC 5 V DC power output to OSS
8 ORGLSWN I 0/5 V DC OSS: On/Off
9 GND - - Ground
YC7 1 +24VSL O 24 V DC 24 V DC power output to DP
Connected
to the
optional DP
2 GND - - Ground
3 +5VSL O 5 V DC 5 V DC power output to DP
4 GND - - Ground
YC8 1 GND - - Ground
Connected
to the
optional DP
2 GND - - Ground
3 GND - - Ground
4 GND - - Ground
5 ORGVSYNC I 0/5 V DC Original scanning interval signal
6 DP_RDY I 0/5 V DC DP ready signal
7 DP_SEL O 0/5 V DC DP select signal
8 SCLK O 0/5 V DC (pulse) DP clock signal
9 SDO O 0/5 V DC (pulse) DP serial communication data signal
10 SDI I 0/5 V DC (pulse) DP serial communication data signal
YC9 1 +24VSL I 24 V DC 24 V DC power input from PSPWB
Connected
to the power
source PWB
2 GND - - Ground
Connector Pin No. Signal I/O Voltage Description