2LK/2LN/2LM/2LC-2
1-3-6
Developer U140 Displaying developer bias
Sleeve DC 62/62/62/62/- 70/70/
70/70/-
70/70/
70/70/70
Sleeve AC 175/175/175/175/- 155/155/
155/155/
-
155/155/
155/155/
155
Mag DC 130/130/130/130/- 155/155/
155/155/
-
155/155/
155/155/
155
Mag AC 101/101/101/101/- 160/200/
200/200/
-
160/200/
200/200/
160
Sleeve Freq 5221/-/
5345/-
5345/-/
5345/-
5345/-/
5345/-
5511/
5345/
5345/
5345
Sleeve Duty 63/- 43/-
43/43
Mag Duty 37/- 68/- 68/68
AC Calib -
Default
15/15/15/12
Mode1
U147 Setting for toner applying operation
Mode Mode1
Upper Limit 2.0
Minimum 10
Interval Number 250/100/50
U148 Setting drum refresh mode 2
U155 Checking sensors for toner -
Supply 512/512/512/512
Empty 100/100/100/100
U156 Setting the toner replenishment level -
U157 Checking the developer drive time -
U158 Checking the developer count -
Fuser U161 Setting the fuser control temperature
Warm Up 155/110/
40/165/
155/150/
50/120
160/110/
40/170/
165/150/
50/120
165/140/
80/170/
165/150/
50/155
170/145/
80/175/
175/150/
50/160
Print 165/5 170/5 170/5 175/5
U163 Resetting the fuser problem data -
U167 Checking/clearing the fuser count -
Section
Item
No.
Content of maintenance item
Initial setting
30ppm 35ppm 45ppm 55ppm