EasyManua.ls Logo

La San Marco 100 E/S PRACTICAL - Water Level and Overfill Alarms; Control Unit and Unselected Water Dispensing; Steam Output and Water Tap Drips

La San Marco 100 E/S PRACTICAL
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
ENGLISH
PROBLEM CAUSE SOLUTION
9.
r0WFSàMMBMBSN r.BMGVODUJPOJOBVUPNBUJDMFWFM
circuit.
r-FBLJOCVUUPOGPSNBOVBM
water lling.
r-FBLJOIFBUFYDIBOHFST
r$IFDLUIFIZESBVMJDDJSDVJUPGUIF
autolevel.
10.
r5IFNBDIJOFJTTXJUDIFE
on (the main switch is in
position 1 or 2 and the
signal light is lit) but the
electronic control is out
of order.
r5IFFMFDUSJDXJSJOHPGUIF
electronic control unit is
defective.
r5IFFMFDUSPOJDDPOUSPMVOJUJT
defective.
r$IFDLUIFFMFDUSJDBMXJSJOHUIF
electronic control unit and its
components.
r3FQMBDFUIFFMFDUSPOJDDPOUSPMVOJU
11.
r5IFNBDIJOFGFFET
water from one serving
unit although the serving
has not been selected.
r4PMFOPJEBOEPSQVNQGFE
continuously.
r$POUSPMVOJUSFMBZQPXFSFE
continuously.
r3FQMBDFUIFFMFDUSPOJDDPOUSPMVOJU
12.
r4NPEFMTPOF
unit serves water
continuously.
r&MFDUSJDDJSDVJUPGVOJU
improperly connected.
r$IFDLUIFDPOOFDUJPOBOEDPSSFDUJU
(see wiring diagram).
13.
r5IFTUFBNFSEJTDIBSHFT
only small quantities of
steam or water droplets.
r5BQOFFETBEKVTUNFOU
r8PSOHBTLFUPOUBQ
r"EKVTUUBQ
r3FQMBDFUIFHBTLFU
14.
r4NBMMESPQTáPXPVUPG
the water tap.
r5BQSFRVJSFTBEKVTUNFOU
S).
r8PSOHBTLFUPOUBQ4
r-FBLJOTPMFOPJEWBMWF&
r"EKVTUUBQ4
r3FQMBDFHBTLFU4
r$IFDLUIFTPMFOPJEWBMWFTIPU
and cold water) and replace as
necessary (100 E).
15.
r5IFVOJUFNJUTBXIJTUMF
after serving the coffee.
r'BVMUZPQFSBUJPOPGFYQBOTJPO
valve.
r)JHIQVNQQSFTTVSF
r$IFDLUIFFYQBOTJPOWBMWFBOEJG
necessary replace it. Calibrate the
valve at 12 bar.
r$IFDLUIFQVNQPQFSBUJOHQSFTTVSF
Calibrate the pump at 9 bar.
16.
r5IFàMUFSDVQDPNFTPGG
the serving unit.
r8PSOHBTLFUVOEFSUIFàMUFS
cup.
r3FQMBDFHBTLFU
r$MFBOUIFTFSWJOHVOJUBOEUIFàMUFS
cup.
17.
r8IFODPGGFFJTCFJOH
served, some of it drips
out of the edge of the
lter cup.
r(BTLFUVOEFSIPMEFSJTXPSO r3FQMBDFUIFHBTLFU
r$MFBOUIFTFSWJOHVOJUBOEUIFàMUFS
cup.
18.
r8BUFSMFBLJOHGSPNUIF
drain of the serving unit
solenoid.
r.BMGVODUJPOJOHVOJUTPMFOPJE
r8BUFSMFBLJOHGSPNVOJU
cooling system.
r$IFDLUIFVOJUTPMFOPJE$IFDLUIF
plunger on the solenoid and clean
the solenoid.
r3FQMBDFUIFBVUPNBUJDMFWFMTPMFOPJE
valve.
r$IFDLUIFTNBMMDPPMJOHUVCFBOE
the related seals of the serving
group (100 DTC).

Table of Contents