16) SWITCHING TO STAND-BY MODE
The standby function automatically turns o󰀨 the electronic circuits of the control unit in case of power failure if the door is closed in the
Night Lock program.
The purpose of this function is to reduce to a minimum the use of the emergency battery to avoid quick draining during power failure.
To enable the stand by function, set the F10 function to ON.
To open the door in standby mode, an input is provided between terminals 28 ‑ 29 (Wake ‑ GND) of the control unit ET‑LOGIC‑B, to which
a device with N.O. contact must be connected.
A pulse on the Wake input allows to turn on the control unit and start door opening at a slow speed.