25
TERMINAL BOARD M3
Terminals 8-11
EXTERNAL RADAR input, N.O. contact.
It controls the door opening.
It is not active when the program selector is set to “Exit Only” and “Night Lock”.
Terminals 9-11
INTERNAL RADAR input, N.O. contact.
It controls the door opening.
It is not active when the program selector is set to “Entry Only” and “Night Lock”.
Terminals 10-11
START input., N.O. contact.
It controls the door opening.
TERMINAL BOARD M4
Connection of the ET-DSEL digital selector
Terminal + = (power supply positive);
Terminal A = signal line A;
Terminal B = signal line B;
Terminal - = (Power supply negative).
TERMINAL BOARD M5 - OUT2
Terminals 22-23-24
Relay potential free contact RL1 (22 = COMMON 23 = N.C., 24 = N.O.)
The output operation depends on the setting of function F41m (see FUNCTION TABLE).
TERMINAL BOARD M6
Terminal 25
TEST output for the safety sensors set for monitoring.
For details, refer to the "Safety sensors" paragraph.
Terminals 26-27
AUX 3 input., N.O. contact.
It is enabled in the applications with interlock (function F26 = ON and F29 = ON).
It controls the door opening in all operating programs.
For details, refer to the "Interlock System" paragraph
Terminals 28-29
Open Collector NPN output.
The operation depends on the setting of function F41m (see FUNCTION TABLE).
Connect a max load of 100mA between terminals 29 (O.C.) and 28 (positive + 24V).
In the Interlock function (F26 = ON), terminal 29 is used for the interlock operation connection; for further information, refer to the
“Interlock system” paragraph.
TERMINAL BOARD M7
Terminals 16 (negative) - 17 (positive)
24Vdc, 1A output supplying power to the control and safety sensors.
When the L1 LED is on, the output is working properly.
TERMINAL BOARD M8
Terminals 18-19-20
Relay potential free contact RL3 for electric lock connection (18 = Common 19 = N.O., 20 = N.C.).
Terminals 16 (negative) - 21 (positive)
24Vdc output supplying power to the electric lock or to the electromagnet.
For details, refer to the paragraph "Applications with electric lock".
CONNECTORS
Connector J1 = connector for digital selector T-NFC
Connector J3 = connection of the battery module NB-BAT (see para. “Battery module NB-BAT”)
Connector J4 = wiring of electrical signals to connector J10 of the LCB logic card.
Connector J5 = wiring of motor power supply to connector J11 of the LCB logic card.
When LED 1 is on the output voltage is present.