PL1220 Owner’s Manual
74
12.4 Before Every Use
• Clean engraving table (work surface)
• Check mirror surfaces (clean only if dirty)
• Check focal lens (clean only if dirty)
• Check the air assist system
12.5 Weekly (10 hours of use)
• Clean venting pathway
• Clean air assist nozzle
• Check belts for debris and lubrication. Lubricate if needed.
• Check linear bearings and guides for debris and lubrication. Lubricate if needed.
12.6 Monthly (100 hours of use)
• Lubricate linear bearings and guides.
• Replace the chiller water.
• Inspect all systems for loose screws and hazards.
• Remove panels and confirm electrical connections.
• Check belts for cracks or frays. Replace if found.
12.7 Yearly (Independent of use)
• Replace water tubing.
• Replace air tubing.
12.8 Cleaning and Lubrication Suggestions
General Cleaning – Soapy water. Do not use chemical cleaners or degreasers.
Glass Cleaning – Microfiber non-scratch cloth and alcohol-based glass cleaner.